Configure WorkZone PDF
Configure WorkZone PDF parameters
It is recommended to perform further configuration in WorkZone Configurator. See WorkZone PDF settings in the WorkZone Configurator Administrator guide.
Configure WorkZone PDF Engine
You can find list of parameters and their descriptions in the WorkZone PDF Engine parameters table.
During installation, you can define WorkZone PDF Engine custom parameters in:
- in WorkZone Configurator – preferable in the WorkZone environment
- in the Web.config file
- as API calls
After installation, you can edit the parameters:
- in WorkZone Configurator – preferable in the WorkZone environment
- in the Web.config file.
The WorkZone PDF Engine Web.config file is located: C:\Program Files (x86)\KMD\WorkZone\IIS\WorkZone\Render
.
You can find API reference documentation under the WorkZone PDF Engine under /Help uri, for example, http://db01/Render/Help.
Any changes to the WorkZone PDF Engine parameter settings will take effect immediately.
The following list illustrates the priority ranking of each WorkZone PDF Engine parameter, with the highest ranked parameter placed first.
- Body: Parameters specified in the body of the request.
- HTTPS Header: Parameters specified in the request header of the API call.
- Database settings: WorkZone PDF Engine settings specified by using the WorkZone Configurator or by using the ScanSQL program directly into the database in the WZPDF_CONFIGURATION table.
- Web.config settings: Settings specified in the Web.config file.
- Installation default values: the settings specified when the WorkZone PDF Engine was initially installed.
You can define parameters for each instance of the WorkZone PDF Engine, enabling you to set different parameters for the various usages you might invoke for the WorkZone PDF Engine, for example, defining parameters for creating pdf documents through the PDF Engine and then defining parameters for the same PDF Engine but different instance when used by the WorkZone SmartPost module.
Create parameter settings for PDF Engine instances
Since WorkZone PDF Engine custom parameter settings are stored in the WZPDF_CONFIGURATION table, you should first create the parameter settings in the WZPDF_CONFIGURATION table for each instance you expect to use.
Creating the parameter settings first will give you a list of valid PDF Engine instances as well as their unique names, making it easier to specify which instance to invoke in the PDF Engine Web.config file later.
Entries in the WZPDF_CONFIGURATION table can be made using the ScanSQL program distributed with the WorkZone product.
Example: Create parameter settings for SmartPost PDF Engine instance
In this example, a new set of parameter settings is created in the WZPDF_CONFIGURATION table for the PDF Engine instance named "SmartPost".
INSERT INTO WZPDF_CONFIGURATION(TARGET, NAME, CUSTOM_VALUE)
VALUES('SmartPost', 'Watermark', 'PROTECTED COPY');
Unique instance names
You must uniquely name each PDF Engine instance (for example, RenderForProcess, RenderForMobile, etc.) you expect to use in the Target field of the WZPDF_CONFIGURATION table.
Once you have created the PDF Engine instances you want to use and defined the custom parameters for each individual instance, these parameters will be applied to the invoked instance.
Default instances
The WZPDF_CONFIGURATION table contains one named instance with the default value: PDFENGINE. You can specify as many instances in the WZPDF_CONFIGURATION table as you need.
Configure WorkZone PDF Crawler
You can set up custom parameters at the time of installation, see Install or update database configuration settings. After the installation, you can set up custom parameters through WorkZone Configurator, see Configure WorkZone PDF.
If you set custom parameters via WorkZone Configurator, the changes will take effect in the next service iteration. A regular service iteration takes a few minutes, but it depends on the number of files, their size, and different settings.
Alternatively, you can define the configuration settings directly in the WZPDF_CONFIGURATION table using SQL scripts or through the ScanSQL program. Parameters will be applied to all instances of the WorkZone PDF Crawler.
Parameter | Description |
---|---|
ProcessingRetries |
Specifies how many times WorkZone PDF Crawler tries to convert a document. The parameter is used when document conversion exceeds The default value is 3. |
ProcessingTimeout |
Specifies a time-out for conversion. When time-out is exceeded, an error message is written to the DVS_RENDER_MESSAGE table. The default value is 5 minutes. |
In order to support offloading and different scalability scenarios, you can install the WorkZone PDF Engine on separate web servers and then create redirect rules from one server to another or to a farm of servers, each with a WorkZone PDF Engine installed.
The redirect rules can be defined on the web server using Microsoft Internet Information Services (IIS) configuration settings.
For more information on defining redirect rules, see HTTP redirects.