Updated: 01/10/2024
The Process Dispatchers Module
The Process Dispatchers module is used to configure dispatchers used by the SmartPost process in WorkZone Process. You can set up three types of dispatchers:
Depending on the type of dispatcher, you can fill in the following settings.
The settings below apply to the EBoks dispatcher.
Name | Default setting | Description |
---|---|---|
URL |
|
The URL for the e-Boks service. Enter one of the URLs depending on whether the configuration is made for test or production. Test system: Production system: |
SenderSystemId |
|
The sender system identifier, which is retrieved during the configuration of the system in the e-Boks administration portal. |
ReceiverSystemId |
The receiver system identifier, which is retrieved during the configuration of the system in the e-Boks administration portal. |
|
CertificateThumbPrint |
Enter the thumbprint that identifies the e-Boks certificate. |
|
SecurityProtocol | Tls12 |
Denotes the security protocol to be used when communicating with e-Boks. e-Boks provides the security protocol to be used. |
MaxDocumentSize | 7864320 (7.5 megabytes) |
The maximum number of bytes that an e-Boks message can contain.
Messages that exceed this limit will not be sent to e-Boks.
The default value is 7864320 (7.5 megabytes).
|
ResponseThreshold | 1800 |
Defines the maximum time that SmartPostexpects that it takes e-Boks to process a message. This value is used to calculate the deadline (supervised by the deadline monitor). Specify the threshold in seconds. The default value is 1800 seconds (30 minutes). The default value is most often used. In situations where the communication with e-Boks is slow, you can increase it. In test scenarios, you can reduce the threshold, which reduces the time before a smartmail with information about an exceeded deadline is sent. |
The settings below apply to the Straalfors dispatcher type.
Name | Default setting | Description |
---|---|---|
Url |
The URL for the Strålfors Connect service. Depending on whether the configuration is made for test or production, enter one of the two URLs. Test: https://itestprint.sconnect.dk/fjernprint/1.0.0 Production: https://prodprint.sconnect.dk/fjernprint/1.0.0 |
|
SenderSystemID | The system identifier, which is provided when configuring the system in the Strålfors administration portal. Either Strålfors or the person, who configures the portal for Straalfors, must provide this identifier | |
CertificateThumbprint |
Enter the thumbprint that identifies the Strålfors certificate. |
|
SecurityProtocol | Tls |
The security protocol to be used when communicating with Strålfors. Strålfors determines which security protocol to use. The default value is Tls (TLS 1.0). If you run Microsoft Windows Server 2012 R2, you can set it to Tls12 (TLS 1.2). If you run Microsoft Windows Server 2008 R2, it is possible to set this to Tls12 (TLS 1.2), but it requires an additional configuration. See the Microsoft article TLS/SSL Settings for more information. The setting is case sensitive and must be written as Tls. |
MaxDocumentSize | 50000000 (50 megabytes) |
The maximum number of bytes that a message for remote print can contain. Messages that exceed this limit will not be sent for remote print. The default value is 50000000 (50 Mb). Unless otherwise communicated, it is recommended to keep the values provided at the installation. |
StraalforsResponseThreshold | -1 |
Defines the maximum time that SmartPost expects that it takes to send a message to Strålfors. This value is used to calculate the deadline (supervised by the deadline monitor). The value is an integer, which (if positive) specifies the threshold in seconds. If the value is zero or negative, SmartPost uses a more advanced algorithm to determine the deadline, which depends on the weekday, the type of letter, and the time of the day. If no value is specified, the advanced algorithm is used. Normally, the default setting is used. If the communication with Strålfors is very slow, you can specify a high value. In test scenarios, you can set the threshold to a low value (but not zero), which means that the deadline will be quickly exceeded. |
SenderName | The name of the company that is used in the postal address. The postal address is used when Strålfors produces the letters. The value should be taken from the address on which the authority will receive postal letters and returned mails. |
The settings below apply to the LocalPrint dispatcher type.
Name | Default setting | Description |
---|---|---|
LocalPrintResponseThreshold | 1800 |
Defines the maximum time that SmartPost expects that it takes for local print to process a message. This value is used to calculate the deadline (supervised by the deadline monitor).
Specify the threshold in number of seconds.
The default value is 1800 seconds (30 minutes). The default value is most often used. |
SenderName | Not used. |